FIRE ALARM SYSTEM

· Fire Alarm System will be operated with the coordination of the building automation system, elevators and public address system. · Fire Alarm System is designed according to NFPA, NEC and UL standards and also the norms of international insurance companies are taken into consideration. · In the Fire Alarm System, electronic (digital) addressable photoelectric type smoke sensors will be used in the offices and in the areas where people work. Ionisation type of smoke sensors will be used in the warehouse and in the electrical rooms. Heat sensors will be used in the mechanical rooms and elevator mechanical rooms. · Fire alarm system cables will be installed up to the main door of the offices at the tenant' s floors and all other operations inside tenant' s office will be done by tenants with approval of management of tower. · Electronic (digital) addressable monitor modules will be used for monitoring of both water flow switches and valve interference switches. Manuel alarm touch buttons will be used for warning. · Warning of Fire Alarm System will be done both with voice and light. Voice warning will not done by sirens. It will be done over loudspeakers via digital recorded announcement from Fire Alarm Centre · Fire Announcement System is independent from general public address system and cooperates with Fire Alarm System. · % 50 spare parts is available in Fire Warning System. Fire announcement system is designed to make announcement independently to each floor and also it is possible to make announcement to fire staircases, elevators, garage and technical areas. · The warning will be done by strobes installed near the loudspeaker. Strobe flashes will work with 24 V. · Fire telephones will be addressable and all will be connected directly to fire telephone central. The main purpose of these telephones is for the confirmation by fire fighting personal whether there is fire or not. · Fire Alarm Panels will directly be connected to UPS System. Fire Alarm Panels will have battery back up which supplies 24 hours stand by energy to the panel and in case of energy cut these batteries will supply energy of 5 minutes at full load. · Fire alarm panels will have 4 loops that can be connected 125 detectors and 125 button/modules. Cabling will be Class A type. There is % 30 spare parts for each loop and in addition, one spare loop card will be installed to each Fire Alarm Panel. · All fire alarm system cables will be fire-retardant and halogen free type.

 
HOMEPAGE
Notice : Technical specifications and material and equipment that are chosen reflects the status of the building as March 2002. Landlord has the right to change the material and equipment at any time, while maintaining the same standard in the building.